TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0600-03 Main Hydraulic
Pump Discharge Pressure
for resistance between cab lower
Proceed to Test Step 5.
Sensor Voltage Above
wiring harness connector P-C41
Normal - Continued
(WP 0009, Figure 68) terminal 22
Proceed to Test Step 4.
and terminal 13.
Resistance should be 5.0 ohms or
less.
Test Step 4. Test for Open Rear
Chassis Wiring Harness.
1. Disconnect the rear chassis wir-
ing harness connector FA-C22
(WP 0009, Figure 47) from cab
lower wiring harness connector P-
C69 (WP 0009, Figure 46) (WP
0188).
2. Disconnect the rear chassis wir-
ing harness connector FA-C23
(WP 0009, Figure 17) from cab
lower wiring harness connector P-
C71 (WP 0009, Figure 18) (WP
0188).
for resistance between rear chas-
Replace cab lower wiring harness
sis wiring harness connector FA-
(WP 0266).
C23 (WP 0009, Figure 17) termi-
Remove jumper wire between rear
nal 3 and connector FA-C22 (WP
chassis wiring harness connector FA-
0009, Figure 47) terminal 25.
C6 (WP 0009, Figure 212) terminal 1
Resistance should be 5.0 ohms or
and terminal 2.
less.
Connect the rear chassis wiring
harness connector FA-C6 (WP 0009,
Figure 212) to hydraulic oil
temperature sensor (WP 0059).
Proceed to step 4.
Replace rear chassis wiring harness
(WP 0188).
Connect the cab lower wiring harness
connector P-C41 (WP 0009, Figure
68) to implement ECM J1 (WP 0009,
Figure 69) (WP 0268).
Proceed to step 4.
4. Using the MSD (WP 0006), select 0600-03 Code Active - Repeat
Implement 120M and verify 0600- troubleshooting code from the
03 is not active.
beginning.
0600-03 Code Not Active -
Troubleshooting complete.
0026-90