TM 5-3805-293-23-1
0016
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0168-02 Electrical System
No Continuity or Resistance More
Voltage Data Erratic, Inter-
continuity between harness con-
Than 5.0 Ohms - Verify rear frame
mittent, or Incorrect - Con-
tinued
113) terminal 66 and machine
clean and tight. If rear frame ground is
ground.
OK, replace rear chassis wiring har-
ness (WP 0188).
ohms.
Proceed to step 9.
No Continuity or Resistance More
continuity between harness con-
Than 5.0 Ohms - Verify rear frame
113) terminal 67 and machine
clean and tight. If rear frame ground is
ground.
OK, replace rear chassis wiring har-
ness (WP 0188).
ohms.
Proceed to step 9.
No Continuity or Resistance More
continuity between harness con-
Than 5.0 Ohms - Verify rear frame
113) terminal 70 and machine
clean and tight. If rear frame ground is
ground.
OK, replace rear chassis wiring har-
ness (WP 0188).
ohms.
Proceed to step 9.
ECM (WP 0137).
Proceed to Step 9.
0168-02 Code Remains Active -
Trans/Chassis 120M and verify
Repeat troubleshooting from the
0168-02 is not active.
beginning of this diagnostic code.
0168-02 Code Not Active - Trouble-
shooting complete.