TM 5-3805-261-34
HYDRAULIC SYSTEM MAINTENANCE.
10-4.
Pump Assembly. (Sheet 15 of 23)
ASSEMBLY
20.
Install stop angle bar on swash-
plate (132, Figure 10-52). Stop
angle bar must be installed with
the deepest point of the two
angles toward the minimum stop
bolt (106). The stop angle bar
must be at a 90 degree angle to a
line through the center of two
bearings (104).
21.
Position gage bar and depth gage
on body (118) with the edge
against dowel (129, Figure
10-53). Install depth gage in
one of the holes in the gage bar
that is directly over the deepest
angle of stop angle bar. The
gage bar must be parallel with
the centerline of two bearings
(104).
22.
Move swashplate (132) until it
makes contact with bolt (109,
Figure 10-54).
23.
Adjust bolt (109) for maximum
swashplate (132) angle. Use
depth gage and measure the
distance from the top of gage bar
to the angle on the stop angle
bar. Move the depth gage to the
hole on the same side of the gage
bar, over the same angle of the
stop angle bar. Measure the
distance from the top of the gage
bar to the angle on the stop
angle bar. Adjust bolt (109)
until the measurements made from
the top of the gage bar to the
angle on the stop angle bar is
the same.
Go to Sheet 16
Figure 10-52.
Figure 10-53.
Figure 10-54.
10-29