TM 5-3805-261-34HYDRAULIC SYSTEM MAINTENANCE.10-4.PumpAssembly. (Sheet 15 of 23)ASSEMBLY20.Install stop angle bar on swash-plate (132, Figure 10-52). Stopangle bar must be installed withthe deepest point of the twoangles toward the minimum stopbolt (106). The stop angle barmust be at a 90 degree angle to aline through the center of twobearings (104).21.Position gage bar and depth gageon body (118) with the edgeagainst dowel (129, Figure10-53). Install depth gage inone of the holes in the gage barthat is directly over the deepestangle of stop angle bar. Thegage bar must be parallel withthe centerline of two bearings(104).22.Move swashplate (132) until itmakes contact with bolt (109,Figure 10-54).23.Adjust bolt (109) for maximumswashplate (132) angle. Usedepth gage and measure the‘distance from the top of gage barto the angle on the stop anglebar. Move the depth gage to thehole on the same side of the gagebar, over the same angle of thestop angle bar. Measure thedistance from the top of the gagebar to the angle on the stopangle bar. Adjust bolt (109)until the measurements made fromthe top of the gage bar to theangle on the stop angle bar isthe same.Go to Sheet 16Figure 10-52.Figure 10-53.Figure 10-54.10-29