STARTING SYSTEM MAINTENANCE. (cont)
4-9.
Starting Motor (Delco-Remy). (Sheet 6 of 15)
DISASSEMBLY (cont)
31.
Remove five bolts (51, Figure
4-46).
32.
Separate housing (57) from
housing (66).
33.
Remove and discard preformed
packing (52) and seal (53).
34.
Drill hole in cup (54) and pry
out of housing (57). Discard cup
(54).
35.
Remove wick (55).
Figure 4-46.
NOTE
Removal of bushing from
housing will cause destruc-
tion of bushing. Remove
bushing only if inspection
indicates replacement is
necessary.
36.
Inspect bushing (56) and if
necessary, using a suitable
driver and press, remove bushing
(56) from housing (57).
Go to Sheet 7
4-42