TM 5-3805-261-23-2
MAIN WIRING HARNESS REPLACEMENT - CONTINUED
0286 00
REMOVAL
NOTE
Tag and note routing of wiring harness before disconnecting to aid in installation.
1.
Disconnect main wiring harness (15) from ether start valve (1) (WP 0050 00), alternator (14) (WP 0066 00), starting
motor (12) (WP 0067 00), air pressure and hourmeter gauges (3) (WP 0252 00), oil pressure and hourmeter switches (2)
(WP 0113 00), ether start temperature switch (4) (WP 0114 00), fuse box (11) (WP 0096 00), stop light switch (9) (WP
0108 00), blade float limit switch (CCE machine) (8) (WP 0093 00), dimmer switch (7) (WP 0103 00), and EMS panel
(6) (WP 0069 00).
2.
Remove clips (5), clamps (10), and tie straps (13). Discard tie straps.
3.
Remove main wiring harness (15) from machine.
1
2
4
3
15
6
5
14
7
13
12
9
11
8
10
397-4087
0286 00-2