TM 5-3805-261-23-1
REMOTE START PANEL REPLACEMENT (TYPE II MACHINE) - CONTINUED
0258 00
REMOVAL - CONTINUED
8.
Disconnect four wires from back of circuit breaker switch (11).
9.
Remove two mounting screws and nuts (10) and remove circuit breaker switch (11) from remote start panel (9).
10.
Remove four mounting nuts and bolts (1) and remove remote start panel (9) from machine.
14
1
1
8
14
5
13
10
11
397-2456
9
10
1
1
CLEANING AND INSTALLATION
Clean and inspect all parts in accordance with WP 0020 00.
INSTALLATION
1.
Install remote start panel (9) and four mounting nuts and bolts (1).
2.
Install circuit breaker switch (11) and two mounting screws and nuts (10).
3.
Install remote battery disconnect (8) and jamnut (7) and install key (6).
4.
Install ether switch (13) and jamnut (12).
5.
Install ether switch button (2) and screw (3).
6.
Install start switch (5) and rubber boot (4).
7.
Connect all wires.
8.
END OF WORK PACKAGE
0258 00-3