TM 5-3805-261-23-1
HYDRAULIC CONTROL LINKAGES MAINTENANCE - CONTINUED
0218 00
REMOVAL - CONTINUED
1.
Remove bolt (1) and lockwasher (2). Discard lockwasher.
2.
Remove rod end (7) and nut (6) from rod (5).
NOTE
Control levers must be out of alignment to provide adequate clearance for removal of pins and bolts.
3.
Remove cotter pin (4), pin (3), and rod (5). Discard cotter pin.
2
1
7
6
5
4
3
397-703
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP 0020 00.
INSTALLATION
1.
Install rod (5), pin (3), and new cotter pin (4).
2.
Install nut (6) and rod end (7).
3.
Install new lockwasher (2) and bolt (1).
0218 00-2