TM 5-3805-261-23-1
HYDRAULIC CONTROL LINKAGES MAINTENANCE - CONTINUED
0218 00
ADJUSTMENT
NOTE
The following is an adjustment procedure for the scarifier control lever. The adjustment procedure for the
remaining control levers is identical.
1.
Remove bolt (1) and lockwasher (2).
2.
Loosen nut (6) on rod (5).
3.
Adjust rod end (7) on rod (5) so that bolt (1) will slide through rod end (7) without putting tension on bolt when
installed.
4.
Install new lockwasher (2) and bolt (1).
5.
Tighten nut (6) on rod (5) against rod end (7).
6.
END OF WORK PACKAGE
0218 00-3