TM 5-3805-261-23-1
BACKUP ALARM SWITCH MAINTENANCE - CONTINUED
0122 00
REMOVAL - CONTINUED
4.
Remove nut (8) and magnet assembly (7) from weld-
ment (9) inside operator panel console.
9
7
8
397-362
DISASSEMBLY
1.
Loosen nut (15) and remove nut (17), stud (16), and nut from magnet holder (14).
2.
Remove retaining ring (10), disk (11), magnet (12), and filter (13) from magnet holder (14). Discard retaining ring.
10
11
12
13
14
15
16
397-363
17
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP 0021 00.