TM 5-3805-261-23-1
BACKUP ALARM SWITCH MAINTENANCE - CONTINUED
0122 00
INSTALLATION - CONTINUED
6
5
4
3
397-2106
2 1
ADJUSTMENT
1.
Position transmission control lever in reverse (TM 5-
3805-261-10).
2.
Adjust nuts (15 and 17) until a clearance of 0.2 +/- 0.1
in. (5 +/- 2 mm) is made between magnet assembly (7)
and switch (3).
3.
Tighten nuts (15 and 17) against weldment (9) inside
operator panel console.
3
CLEARANCE
7
15
9
17
397-2107
4.
Install left and right side plates on operator panel console (WP 0193 00).
5.
END OF WORK PACKAGE