TM 5-3805-261-23-1
BACKUP ALARM SWITCH MAINTENANCE - CONTINUED
0122 00
ASSEMBLY
NOTE
Side of magnet with part number stamped on it must face disk.
1.
Install filter (13), magnet (12), disk (11), and new retaining ring (10) in magnet holder (14).
2.
Install nut (15) loosely on stud (16) and install stud in magnet holder (14).
3.
Apply thread sealant to threads of stud (16) and tighten nut (15) against magnet holder (14) to 18 lb-ft (24 Nm).
4.
Install nut (17) loosely on stud (16).
10
11
12
13
14
15
16
397-363
17
INSTALLATION
1.
Install magnet assembly (7) and nut (8) loosely on
weldment (9) inside operator panel console.
9
7
8
397-362
2.
Install new lockwasher (4) and nut (5) on switch (3).
3.
Install switch (3), new lockwasher (2), and nut (1).
4.
Connect two wire assemblies (6) to switch (3).
0122 00-4