TM 5-3805-261-23-1
BACKUP ALARM SWITCH MAINTENANCE - CONTINUED
0122 00
REMOVAL
NOTE
Tag wire assemblies before disconnecting to aid in installation.
1.
Disconnect two wire assemblies (6) from switch (3) inside operator panel console.
2.
Remove nut (1), lockwasher (2), and switch (3). Discard lockwasher.
3.
Remove nut (5) and lockwasher (4) from switch (3). Discard lockwasher.
6
5
4
3
397-361
2
1