TM 5-3805-261-23-1
MISCELLANEOUS TROUBLESHOOTING PROCEDURES - CONTINUED
0013 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
If operator panel console slips out of
To adjust cylinder (3), screw cylinder rod
6.
Operator Panel Console
position, adjust.
Moves Out of Adjustment or
into retainer assembly (1) until valve stem
Does Not Lock Into Position.
(5) makes contact with ball (2). Then
loosen cylinder rod one complete turn and
tighten jamnut (4). Cylinder can then be
rotated for alignment after jamnut is
tightened. If the problem still exists, go to
Test 2.
1
5
2
4
3
397-2384
2.
If operator panel is spring-type and
does not lock.
1.
Check main circuit breaker (60A).
Reset circuit breaker. If the problem still
7.
All Windshield Wipers and
Washers Fail to Operate
exists, go to Test 2.
(CCE Machine).
2.
Check windshield wiper fuse (4A).
the problem still exists, go to Test 3.