TM 5-3805-261-23-1
MISCELLANEOUS TROUBLESHOOTING PROCEDURES - CONTINUED
0013 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Check differential lock valve.
If lock valve is worn, damaged, or
16. Differential Lock Is Not
Engaging Correctly -
defective, replace (WP 0306 00). If the
Continued.
problem still exists, go to Test 3.
3.
Check differential lock.
Replace lines as necessary. If the problem
still exists, go to Test 4.
4.
Check lines for air leaks.
Replace lines as necessary.
1.
Check control valve.
If control valve is worn, damaged, or
17. Differential Lock Is Not
Releasing Correctly.
defective, replace (WP 0306 00). If the
problem still exists, go to Test 2.
2.
Check differential lock valve.
If lock valve is worn, damaged, or
defective, replace (WP 0306 00). If the
problem still exists, go to Test 3.
3.
Check lines for air leaks.
Replace lines as necessary.
END OF WORK PACKAGE