TM 5-3805-261-20
Section XVI. FUSE BOX TROUBLESHOOTING.
7-57.
GENERAL INFORMATION. This section lists the common fuse box malfunctions which may occur during the
operation of the 130G Grader. You should perform the tests, inspections and corrective actions in the order listed. Follow
the troubleshooting procedures listed below step-by-step until you can go no further.
7-58.
FUSE BOX TROUBLESHOOTING PROCEDURES. This section cannot list all possible malfunctions, nor can it
list all possible tests, inspections or corrective actions. If a malfunction is not listed, contact your supervisor.
FUSE BOX TROUBLESHOOTING AND MAINTENANCE PROCEDURES.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a.
FUSE BOX LOOSE.
Check the fuse box mounting bolts (Figure 7-76).
Figure 7-76
If the fuse box mounting bolts are loose--tighten. If the fuse box mounting bolts are damaged or defective--
replace. Refer to paragraph 7-62.
b.
FUSE BOX DOOR WILL NOT CLOSE.
Check fuse box hinges for binding.
If the hinges are damaged or defective--replace. Refer to paragraph 7-62.
7-139