TM 5-3805-261-20COOLING SYSTEM MAINTENANCE.6-45.FanLubricationLine.(Sheet 2 of 3)REMOVAL1.Open left side screen door. Refer toparagraph 6-49, steps 1 and 2.2.Remove union (2).NOTEAll hose and tube assemblies must betagged before disconnecting to aid ininstallation. Cap all hose and tubeends to prevent contamination.3.Remove bolt (4), washer (5) and clip (6).4.Disconnect hose assembly (3) from bracket(7).5.Remove hose assembly (3).CLEANINGClean all parts. Refer to Chapter 2.INSPECTIONInspect all parts. Refer to Chapter 2.Figure 6-110.Go to Sheet 36-159