TM 5-3805-261-20
FUEL SYSTEM MAINTENANCE.
6-27.
Ether Starting Aid Cylinder. (Sheet 2 of 2)
REMOVAL
WARNING
Starting fluid is toxic and highly
flammable. Container is pressurized
to act as an expellent. Do not heat
container. Do not discharge ether in
confined areas or near an open flame.
Failure to follow this procedure may
cause INJURY.
1.
Loosen wing nut and clamp (Figure 6-78)
behind right fan guard.
2.
Remove and discard ether starting aid
cylinder by turning counter-clockwise.
CLEANING
Clean all parts. Refer to Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter 2.
INSTALLATION
1.
Install new ether starting aid cylinder (Figure
6-78) by turning clockwise.
2.
Tighten clamp and wing nut.
NOTE
Return
130G
Grader
to
original
equipment condition.
Figure 6-78.
End of Task
6-103