TM 5-3805-261-20FUEL SYSTEM MAINTENANCE.6-27.EtherStartingAidCylinder.(Sheet 2 of 2)REMOVALWARNINGStarting fluid is toxic and highlyflammable. Container is pressurizedto act as an expellent. Do not heatcontainer. Do not discharge ether inconfined areas or near an open flame.Failure to follow this procedure maycause INJURY.1.Loosen wing nut and clamp (Figure 6-78)behind right fan guard.2.Remove and discard ether starting aidcylinder by turning counter-clockwise.CLEANINGClean all parts. Refer to Chapter 2.INSPECTIONInspect all parts. Refer to Chapter 2.INSTALLATION1.Install new ether starting aid cylinder (Figure6-78) by turning clockwise.2.Tighten clamp and wing nut.NOTEReturn 130G Grader to originalequipment condition.Figure 6-78.End of Task6-103