TM 5-3805-261-20
HYDRAULIC SYSTEM MAINTENANCE. (cont)
15-15.
Articulation Check Valve. (Sheet 3 of 4)
CLEANING
Clean all parts. Refer to Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter 2.
INSTALLATION
1.
Install valve assembly (16), three washers
(15) and bolts (14, Figure 15-23) under
center,
right
side
of
operators
compartment.
2.
Install new preformed packing (13) and
elbow (12).
3.
Connect hose assembly (11).
4.
Install new preformed packing (10) and
elbow (9).
5.
Connect hose assembly (8).
6.
Install new preformed packing (7), fitting (6)
and elbow (5, Figure 15-22).
7.
Install new preformed packing (4) and fitting
(3).
8.
Connect hose assemblies (2 and 1) to
elbow (5) and fitting (3).
Figure 15-23.
Figure 15-22.
Go to Sheet 4
15-52