65. Route block heater fuel supply line (Figure 54, Item 3) on machine.
66. Route fuel supply line (Figure 54, Item 3) through left front engine enclosure side access panel (Figure 54,
Item 1).
67. Install grommet (Figure 54, Item 2) on fuel supply line (Figure 54, Item 3) and left front engine enclosure side
access panel (Figure 54, Item 1).
68. Install new O-ring (Figure 54, Item 4) and fuel supply line (Figure 54, Item 3) on fitting (Figure 54, Item 5).
Figure 54. Fuel Supply Line to Arctic Heater.