6
TM 5-3805-293-23-5
FIELD MAINTENANCE
-
BLADE/MOLDBOARD WEARSTRIP REPLACEMENT
0
306
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-3805-293-10)
0
Articulation lock pin installed
0
Wrench, Torque, Dial, 3/8" Drive, 300 lb-in.
(TM 5-3805-293-10)
0
Moldboard raised and rolled forward
0
(TM 5-3805-293-10)
0
Materials/Parts
0
Drawings Required
0
0
Locknut (6)
TM 5-3805-293-24P, Figure 151
0
0
Wearstrip
0
Estimated Time to Complete
0
References
1.0 Hr
0
0
0
N OT E
The procedure for moldboard wearstrip replacement is identical for left and right sides of
moldboard. Right moldboard wearstrip replacement is shown in this procedure.
REMOVAL
000306
1. Remove six locknuts (Figure 1, Item 1) from blade mount (Figure 1, Item 3). Discard locknuts.
2. Loosen six setscrews (Figure 1, Item 2) on blade mount (Figure 1, Item 3).
Figure 1. Locknut and Setscrews.
0306