PRESSURE SWITCH INSTALLATION
00097
1. Install new O-ring (Figure 3, Item 12) and pressure switch (Figure 3, Item 13) on compressor (Figure 3, Item 6).
2. Install two new O-rings (Figure 3, Item 7) and tubes (Figure 3, Item 8) on compressor (Figure 3, Item 6).
3. Install plate (Figure 3, Item 11), washer (Figure 3, Item 9), and bolt (Figure 3, Item 10) on compressor
(Figure 3, Item 6).
4. Install new tiedown strap (Figure 3, Item 1) on pressure switch harness (Figure 3, Item 2).
5. Install pressure switch connector (Figure 3, Item 5) on clip (Figure 3, Item 4).
6. Connect wiring harness connector (Figure 3, Item 3) to pressure switch connector (Figure 3, Item 5).
Figure 3. Pressure Switch.
0097
7. Evacuate and charge air conditioning system (WP 0295).
END OF TASK
END OF WORK PACKAGE
0097-4