TM 5-3805-293-23-3
0092
INSTALLATION CONTINUED
4. Position dial indicator with magnetic clamp on oil pump idler gear (Figure 3, Item 2).
5. Measure backlash between oil pump idler gear (Figure 3, Item 2) and crankshaft drive gear (Figure 3, Item 1).
Clearance must be 0.0091 in. to 0.0315 (0.23 to 0.80 mm).
Figure 3. Idler Gear Backlash.
0092
END OF TASK
FOLLOW-ON TASKS
00092
END OF TASK
END OF WORK PACKAGE