TM 5-3805-293-23-3
0064
INSTALLATION CONTINUED
6. Install two clamps (Figure 3, Item 5) on machine.
7. Install positive cable (Figure 3, Item 8), FE harness (Figure 3, Item 7), bolt (Figure 3, Item 4), washer (Figure 3,
Item 3) and two clamps (Figure 3, Item 5) to hydraulic service pack.
8. Connect FE harness plug (Figure 3, Item 11) to main harness plug (Figure 3, Item 12).
9. Install new tiedown strap (Figure 3, Item 10) on FE harness (Figure 3, Item 7) and secure to machine.
10. Install new tiedown strap (Figure 3, Item 10) around FE harness plug (Figure 3, Item 11) and main harness
plug (Figure 3, Item 12) and secure to machine.
11. Connect priming pump plug (Figure 3, Item 9) to priming pump (Figure 3, Item 6).
12. Connect fuel pump relay plug (Figure 3, Item 2) to fuel pump relay (Figure 3, Item 1).
Figure 3. FE Harness: Priming Pump and Fuel Pump Relay Plugs.
0064
END OF TASK
FOLLOW-ON TASKS
00064
Connect battery cables (WP 0194).
END OF TASK
END OF WORK PACKAGE