TM 5-3805-293-23-3
0064
REMOVAL
00064
N OT E
Tag and identify all connectors before removal for ease of installation.
1. Disconnect fuel pump relay plug (Figure 1, Item 2) from fuel pump relay (Figure 1, Item 1).
2. Disconnect priming pump plug (Figure 1, Item 9) from priming pump (Figure 1, Item 6).
3. Remove tiedown strap (Figure 1, Item 10) from FE harness plug (Figure 1, Item 11). Discard tiedown strap.
4. Disconnect FE harness plug (Figure 1, Item 11) from main harness (Figure 1, Item 12).
5. Remove bolt (Figure 1, Item 4), washer (Figure 1, Item 3), FE harness (Figure 1, Item 7), positive cable
(Figure 1, Item 8) and two clamps (Figure 1, Item 5) from hydraulic service pack.
Figure 1. FE Harness: Priming Pump and Fuel Pump Relay Plugs.
0064
6. Disconnect ether aid solenoid plug (Figure 2, Item 5) from solenoid connector (Figure 2, Item 4).
N OT E
An additional clamp may be present on machine if machine is equipped with an arctic
heater.
7. Remove bolt (Figure 2, Item 1), washer (Figure 2, Item 2), two clamps (Figure 2, Item 3) and spacer (Figure 2,
Item 10) from hydraulic service pack.
8. Disconnect turbocharger inlet pressure sensor plug (Figure 2, Item 8) from sensor connector (Figure 2, Item 9).