COOLING FAN WIRING HARNESS REPLACEMENT
Figure 3. Fan Wiring.

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  356    357    358    359    360  361  362    363    364    365    366  
img
.
TM 5-3805-293-23-3
0058
REMOVAL CONTINUED
N OT E
Tag and mark wires to aid in installation.
2. Disconnect two electrical connectors (Figure 2, Item 1) from fan wire harness (Figure 2, Item 2).
Figure 2. Connector.
0058
3. Remove six tiedown straps (Figure 3, Item 2) from fan wiring harness (Figure 3, Item 1). Discard tiedown
straps.
4. Disconnect electrical connector (Figure 3, Item 6) from main machine wiring (Figure 3, Item 7).
5. Remove three bolts (Figure 3, Item 8), washers (Figure 3, Item 9), and two clamps (Figure 3, Item 3) from
machine.
6. Remove two nuts (Figure 3, Item 5) and clamp (Figure 3, Item 4) from machine.
7. Remove fan wiring harness (Figure 3, Item 1) from machine.
0058-2