TM 5-3805-293-23-3
0049
INSTALLATION CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure any lifting device used is in good condition and of
suitable load capacity. Keep clear of heavy parts supported only by lifting device. Failure to
follow this warning may result in injury or death to personnel.
N OT E
Cooling module weighs 610 lb (277 kg).
2. Using lifting device, feed hoses (Figure 42, Item 4) through cooling module and install cooling module on
machine.
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of clean up rags IAW local policy
and ordinances. Failure to follow this warning may cause injury to personnel.
3. Apply sealing compound to four new bolts (Figure 42, Item 1).
4. Install four washers (Figure 42, Item 2) and bolts (Figure 42, Item 1) on cooling module (Figure 42, Item 3).
Torque bolts to 250 lb-ft (339 Nm).
Figure 42. Cooling Module Bolts.
0049