10. Install clip (Figure 47, Item 22), washer (Figure 47, Item 20) and bolt (Figure 47, Item 21) on bracket (Figure
47, Item 24).
11. Install nut (Figure 47, Item 14), washer (Figure 47, Item 15), clip (Figure 47, Item 16), clip (Figure 47, Item 19),
washer (Figure 47, Item 17), and bolt (Figure 47, Item 18) on hose (Figure 47, Items 1 and 11),
12. Install nut (Figure 47, Item 7), washer (Figure 47, Item 6), spacer (Figure 47, Item 5), clip (Figure 47, Item 4),
washer (Figure 47, Item 3), and bolt (Figure 47, Item 2) on cooling fan gear motor frame (Figure 47, Item 23).
13. Connect electrical connector (Figure 47, Item 12) to backup alarm (Figure 47, Item 13).
14. Install new O-ring (Figure 47, Item 10) and connect hose (Figure 47, Item 11) on block (Figure 47, Item 8).
15. Connect electrical connector (Figure 47, Item 9) to block (Figure 47, Item 8).
Figure 47. Drain Line Clamps and Electrical Connector.