Figure 92. 100 Percent Override Display.
Figure 94. Hose.

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
img
. .
TM 5-3805-293-23-3
0043
SOLENOID (MOTOR DISPLACEMENT) TEST CONTINUED
00043
31. Record value from gauge (Figure 93, Item 1) for right motor displacement at test port.
a.
If there is a change in speed ratio that was recorded in step 27 and pressure at port is greater than
106126 psi (800 kPa), replace solenoid (WP 0248).
b.
If there is a change in speed ratio that was recorded in step 27 and pressure at port is less than
106126 psi (800 kPa), replace right drive motor (WP 0164).
c.
Select Disable All Overrides button and parameters will reset to normal.
Figure 93. Pressure at Test Port (Left).
0043
32. Shut down machine (TM 5-3805-293-10).
0043-77