Figure 88. 45 Percent Override Display.
Figure 90. 45 Percent Override Display.

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
img
. .
TM 5-3805-293-23-3
0043
SOLENOID (MOTOR DISPLACEMENT) TEST CONTINUED
00043
23. Record value from gauge (Figure 89, Item 1) for left motor displacement at test port.
a.
If there is a change in speed ratio that was recorded in step 19 and pressure at port is greater than
116 10 psi (800 kPa), replace solenoid (WP 0248).
b.
If there is a change in speed ratio that was recorded in step 19 and pressure at port is less than 116
10 psi (800 kPa), replace left drive motor (WP 0165).
Figure 89. Pressure at Test Port (Left).
0043
0043-73