Figure 91. Diagnostic Display.
Figure 93. Pressure at Test Port (Left).

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  71    72    73    74    75  76  77    78    79    80    81  
img
.
TM 5-3805-293-23-3
0043
SOLENOID (MOTOR DISPLACEMENT) TEST CONTINUED
00043
26. Select Right Front Drive Pump Forward Control Solenoid Current Percentage Override (Figure 92, Item 5) and
select Change button (Figure 92, Item 4).
27. Enter value of 100 in New Value box (Figure 92, Item 3) and select OK button (Figure 92, Item 2). Record
value of Right Front Speed Ratio value (Figure 92, Item 1). Value should be between 0.7 and 0.745.
Figure 92. 100 Percent Override Display.
0043
28. Select Right Front Drive Motor Solenoid Current Percentage Override (Figure 92, Item 5) and select Change
button (Figure 92, Item 4).
29. Enter value of 45 in New Value box (Figure 92, Item 3) and select OK button (Figure 92, Item 2).
30. Record value of Right Front Speed Ratio (Figure 92, Item 1). Value should not change from value of step 27 by
more than 0.005.
0043-76