TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2163-03 Blade Right Lower
System Response:
Solenoid Voltage Above Nor- ECM will log a diagnostic code.
mal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2163-03
is Active.
1. Connect MSD (WP 0006). Select 2163-03 Code Active - Proceed to
Implement 120M and verify 2163- Test Step 2.
03 is active.
2163-03 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Implement 1 ECM.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
2. Remove rear front frame cover
(WP 0224).
3. Disconnect front attachment har-
ness connector U-C22 (WP 0009,
Figure 236) from blade right lower
4. Disconnect cab lower harness
connector P-C41 (WP 0009, Fig-
ure 68) from implement 1 ECM J1
(WP 0009, Figure 69) (WP 0268).
continuity between harness con-
nector P-C41 (WP 0009, Figure
ECM (WP 0268).
68) terminal 62 and all other ter-
Connect front attachment harness
minals on harness connector P-
connector U-C22 (WP 0009, Figure
C41.
236) to blade right lower solenoid (WP
There should be no continuity.
0009, Figure 237), and install rear
front frame cover (WP 0224).
Proceed to step 6.
0029-26