Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  795    796    797    798    799  800  801    802    803    804    805  
img
TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2162-05 Blade Left Lower
7. Using digital multimeter, test for
Resistance 5.0 Ohms or Less -
Solenoid Current Below Nor-
continuity between harness con-
Replace implement 1 ECM (WP
mal - Continued
nector P-C41 (WP 0009, Figure
0268).
68) terminal 61 and terminal 60.
Remove jumper wire from harness
Resistance should be less than
connector P-C50 (WP 0009, Figure
5.0 ohms.
120) terminal 20 and terminal 39.
Connect front attachment harness
connector U-C1 (WP 0009, Figure
121) to cab lower harness connector
P-C50 (WP 0009, Figure 120).
Connect front attachment harness
connector U-C24 (WP 0009, Figure
240) to blade left lower solenoid (WP
0009, Figure 241), and install rear
front frame cover (WP 0224).
Proceed to step 8.
Resistance More Than 5.0 Ohms -
Replace cab lower wiring harness
(WP 0266).
Connect front attachment harness
connector U-C24 (WP 0009, Figure
240) to blade left lower solenoid (WP
0009, Figure 241), and install rear
front frame cover (WP 0224).
Proceed to step 8.
8. Using MSD (WP 0006), select
2162-05 Code Active - Repeat
Implement 120M and verify 2162- troubleshooting code from the
05 is active.
beginning.
2162-05 Code Not Active -
Troubleshooting complete.