• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  790    791    792    793    794  795  796    797    798    799    800  
img
.
TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2161-06 Blade Right Raise
6. Using MSD (WP 0006), select
2161-06 Code Active - Repeat
Solenoid Current Above
Implement 120M and verify 2161- troubleshooting code from the
Normal - Continued
06 is active.
beginning.
2161-06 Code Not Active -
Troubleshooting complete.
2161-13 Blade Right Raise
System Response:
Solenoid Out of Calibration
ECM will log a diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2161-13
is Active.
1. Connect MSD (WP 0006). Select  2161-13 Code Active - Proceed to
Implement 120M and verify 2161- Test Step 2.
13 is active.
2161-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2161-03, 2161 05, or 2161-06 Code
2161-03, 2161-05, or 2161-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2161-13 Code Only Active - Proceed
to step 2.
Blade Right Raise Solenoid Cannot
2. Calibrate blade right raise sole-
Be Calibrated - Replace blade right
noid, refer to Any Implement
raise solenoid (WP 0246).
Moves with Joystick in Hold Posi-
tion (WP 0025).
Proceed to step 3.
Blade Right Raise Solenoid
Calibrated - Proceed to step 3.
3. Using MSD (WP 0006), select
2161-13 Code Active - Repeat
Implement 120M and verify 2161- troubleshooting code from the
13 is active.
beginning.
2161-13 Code Not Active -
Troubleshooting complete.
0029-17


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.