Table 1. Window Wipers and Washers Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 7. Test 530-OR Washer
6. RH Door Washer Does
Circuit for High Resistance or Open
Not Work. RH Door
in Cab Lower Wiring Harness.
Wiper is Operational -
Continued
1. Disconnect cab lower wiring har-
ness connector P-C3 (WP 0009,
Figure 34) from cab upper wiring
harness connector R-C1 (WP
0009, Figure 33) (WP 0266).
resistance between P-C3 terminal
Replace cab lower wiring harness
24 (WP 0009, Figure 34) and P-
(WP 0266).
C67 terminal 1 (WP 0009, Figure
Proceed to step 3.
373).
Replace cab upper wiring harness
(WP 0265).
Connect P-C67 (WP 0009, Figure
373) on RH door washer motor (WP
0261).
Proceed to step 3.
3. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-3805-293-10).
4. Turn right door washer control to
Right Door Washer Does Not Oper-
ON position (TM 5-3805-293-10).
ate - Repeat troubleshooting from
beginning.
Right Door Washer Operates - Trou-
bleshooting complete.
END OF WORK PACKAGE