TM 5-3805-293-23-2
0024
Table 1. Window Wipers and Washers Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. RH Door Washer Does
Not Work. RH Door
resistance between cab lower wir-
Proceed to Test Step 4.
Wiper is Operational -
ing harness connector P-C67 ter-
Resistance Less Than 5.0 Ohms -
Continued
minal 2 (WP 0009, Figure 373)
Proceed to Test Step 6.
and machine ground.
Test Step 4. Inspect Ground Points
of Cab Lower Wiring Harness.
Ground Point or Ring Terminal
1. Inspect ground points of cab
Dirty or Corroded - Clean as neces-
lower wiring harness (WP 0009,
sary.
Figure 65) for dirt, corrosion, and
damage.
Connect P-C67 (WP 0009, Figure
373) on RH door washer motor (WP
0261).
Proceed to step 2.
Ring Terminal Defective - Replace
cab lower wiring harness (WP 0266).
Proceed to step 2.
No Problem Found - Install cab lower
wiring harness terminals on ground
point with mounting hardware and
tighten securely.
Proceed to Test Step 5.
2. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-3805-293-10).
3. Turn right door washer control to
Right Door Washer Does Not Oper-
ON position (TM 5-3805-293-10).
ate - Repeat troubleshooting from
beginning.
Right Door Washer Operates - Trou-
bleshooting complete.
Test Step 5. Test 200-BK Ground
Circuit to RH Door Washer Motor
for High Resistance or Open.
resistance between cab lower wir-
Replace cab lower wiring harness
ing harness connector P-C67 ter-
(WP 0266).
minal 2 (WP 0009, Figure 373)
Proceed to step 2.
and machine ground.
Resistance Less Than 5.0 Ohms -
Connect P-C67 (WP 0009, Figure
373) on RH door washer motor (WP
0261).
Proceed to step 2.
0024-89