Table 1. Implement Troubleshooting Procedures - Continued.
Figure 1. Open Session.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  450    451    452    453    454  455  456    457    458    459    460  
img
TM 5-3805-293-23-2
0025
Table 1. Implement Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Any Implement Moves
1. Connect MSD and select
Diagnostic or Event Codes Are
with Joystick in Hold
Implement 120M ECM (WP
Active - Repair diagnostic code (WP
Position
0006), and check for any active
0010).
diagnostic or event codes.
Diagnostic or Event Codes Are
NOT Active - Proceed to step 2.
2. Check for contamination in
Hydraulic Oil Is Contaminated -
hydraulic oil.
Service hydraulic oil (WP 0217) and
replace hydraulic oil filter (WP 0208).
Perform oil configuration (WP 0217).
Hydraulic Oil OK - Proceed to step
3.
3. Check implement and steering
Leaks Identified - Replace leaking
pump lines (WP 0174) for Class
implement and steering pump lines
III leaks.
(WP 0174).
No Leaks - proceed to step 4.
WARN I N G
Implements will move during the calibration procedure. Position
machine away from other objects. Keep personnel away from all imple-
ments. Failure to follow this warning may cause injury or death to per-
sonnel or damage to equipment.
Using MSD (WP 0006) verify
4. Perform Implement Solenoid
Implement 120M ECM is selected
Calibration and calibrate the
(Figure 1, Item 1) from menu on
affected implement solenoid.
screen and select OK button
(Figure 1, Item 2).