TM 5-3805-293-23-2
0024
Table 1. Window Wipers and Washers Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. RH Door Washer Does
Voltage Within 18-26 Volts - Proceed
Not Work. RH Door
for Voltage between R-C32 termi-
to Test Step 2.
Wiper is Operational -
nal 2 (WP 0009, Figure 363) and
Voltage Not Within 18-26 Volts -
Continued
machine ground.
Replace cab upper wiring harness
(WP 0265).
Proceed to step 5.
5. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-3805-293-10).
6. Turn right door washer control to
Right Door Washer Does Not Oper-
ON position (TM 5-3805-293-10).
ate - Repeat troubleshooting from
beginning.
Right Door Washer Operates - Trou-
bleshooting complete.
Test Step 2. Test for Open RH Door
Wiper Washer Switch.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-293-10).
2. Disconnect cab upper wiring har-
ness connector R-C31 (WP 0009,
Figure 367) from LH door wiper
washer switch.
3. Connect cab upper wiring har-
ness connector R-C32 (WP 0009,
Figure 363) on LH door wiper
washer switch.
4. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-3805-293-10).
0024-87