• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  861    862    863    864    865  866  867    868    869    870    871  
img
. . . . . . . . . . . . . . . .
TM 5-3805-293-23-1
0016
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0096-03 Fuel Level Sensor
2. Disconnect harness connector U-
Voltage Above Normal -
C8 (WP 0009, Figure 206) from
Continued
harness connector CF-C1 (WP
0009, Figure 206) (WP 0183).
3. Using digital multimeter, test for
Continuity - Proceed to step 4.
continuity between harness con-
No Continuity - Replace front lighting
nector CF-C3 (WP 0009, Figure
harness (WP 0196).
203) terminal 2 and harness con-
Proceed to step 7.
nector CF-C1 (WP 0009, Figure
206) terminal 2. Resistance
should be less than 5.0 ohms.
N OT E
Harness connector is located behind cab bulkhead cover on right rear
of cab.
4. Remove rear bulkhead cover
plate (WP 0266).
5. Disconnect harness connector
FA-C23 (WP 0009, Figure 17)
from harness connector P-C71
(WP 0009, Figure 18).
6. Using digital multimeter, test for
Continuity - Replace lower cab wiring
continuity between harness con-
harness (WP 0266).
nector P-C71 (WP 0009, Figure
Connect harness connector U-C8
18) terminal 2 machine ground.
(WP 0009, Figure 206) to harness
Resistance should be less than
connector CF-C1 (WP 0009, Figure
5.0 ohms.
206) (WP 0183).
Connect harness connector CF-C3
(WP 0009, Figure 203) from fuel level
sensor (WP 0009, Figure 204) (WP
0196).
Proceed to step 7.
No Continuity - Replace rear chassis
wiring harness (WP 0188).
Connect harness connector U-C8
(WP 0009, Figure 206) to harness
connector CF-C1 (WP 0009, Figure
206) (WP 0183).
Connect harness connector CF-C3
(WP 0009, Figure 203) from fuel level
sensor (WP 0009, Figure 204) (WP
0196).
Proceed to step 7.
0016-22