Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.
Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  474    475    476    477    478  479  480    481    482    483    484  
img
. . . . . . . . . . . .
TM 5-3805-293-23-1
0011
Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.
CDI FMI CODE
ERROR/EVENT
CORRECTIVE ACTION
1834-02 Ignition Key Switch
9. Using a digital multimeter, test for
No Continuity or Resistance More
Loss of Signal - Continued
continuity between PF-C1 (WP
Than Specified Value - Replace
0009, Figure 45) terminal 19 and
instrument panel harness (WP 0276).
ground.
Remove jumper wire between PF-C8
(WP 0009, Figure 36) terminal 1 and
There should be good continuity.
ground.
Connect connector P-C69 (WP 0009,
Figure 46) to connector FA-C22 (WP
0009, Figure 47).
Install rear bulkhead cover plate (WP
0266).
Connect connector FA-C17 (WP
0009, Figure 14) to Engine ECM J1.
Continuity - (Resistance should be
less than 5.0 Ohms) - Replace cab
lower wiring harness (WP 0266).
Connect connector FA-C17 (WP
0009, Figure 14) to Engine ECM J1.
Remove jumper wire between PF-C8
(WP 0009, Figure 36) terminal 1 and
ground.
Connect ignition switch harness
connector PF-C8 (WP 0009, Figure
36) to ignition switch.
Install instrument panel (WP 0276).
2417-05 Ether Injection Con- System Response:
trol Solenoid Current Below  A warning will display on instrument
Normal Code
panel. ECM will log diagnostic code.
Possible Performance Effect:
Ether solenoid will not activate.
ECM will log diagnostic code. A
warning will appear on display on
instrument panel.
0011-177