Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.
CDI FMI CODE
ERROR/EVENT
CORRECTIVE ACTION
0041-04 8 Volt DC Supply
Voltage Below Normal -
continuity between P-C70 (WP
harness is shorted, replace cab lower
Continued
0009, Figure 16) harness connec-
wiring harness (WP 0266).
tor terminal 4 and all other termi-
nals on P-C70, and ground. There
harness connector to throttle position
should be no continuity.
sensor.
Install pedal assembly cover (WP
0288).
harness connector to engine speed
sensor.
harness connector to secondary
engine speed sensor.
Connect Engine ECM harness con-
Engine ECM J2.
Engine ECM (WP 0067).
harness connector to throttle position
sensor.
Install pedal assembly cover (WP
0288).
harness connector to engine speed
sensor.
harness connector to secondary
engine speed sensor.
0011-73
Change 1