TM 5-3805-263-14&P-1
Check the radiator coolant level. Keep the coolant level
above the low fluid level mark and up to the full mark.
Test the Supplemental Steering
A dead cell in the machines batteries will result in a
loss of supplemental steering capability.
NOTICE
Hold the switch in the MANUAL position only long
enough to test the supplemental steering. Do not
exceed five minutes. Allow the pump and solenoid to
cool.
To Test
1.
Turn the disconnect switch ON.
2.
The steering fault indicator
should blink and
the fault light
should flash until the engine is started.
The motor indicator
should go ON for three seconds.
NOTE: While the motor indicator
is ON, the effort
required to steer the machine should be nearly the same
as the effort required when using the machines primary
steering system.
3.
Start the engine. The steering fault indicator and
fault light should go OFF.
33