TM 5-3805-261-34
STARTING SYSTEM MAINTENANCE.
4-11.
Starting Motor (Prestolite). (Sheet 6 of 9)
CLEANING
2.
Remove loose particles from
armature (37, Figure 4-70) with
compressed air and wipe with a
clean cloth dampened with dry
cleaning solvent. Clean
commutator lightly with sandpaper
and remove all traces of dust
with low pressure compressed air.
3.
Clean all other parts. Refer to
Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter 2.
ASSEMBLY
1.
Install stud (62), spacer (61),
lockwasher (60) and bolt (59) to
inside of frame (63, Figure
4-68).
2.
Install spacer (58), stud (57),
lockwasher (56), nut (55),
connector (54), lockwasher (53)
and nut (52) onto bolt (59) on
outside of frame (63).
3.
Install coil (51) into frame (63,
Figure 4-67).
4.
Install four studs (50) and
screws (49).
5.
Install three screws (48).
Figure 4-67.
Go to Sheet 7
4-61
Figure 4-70.
Figure 4-68.