TM 5-3805-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL
HOURS
h. Check for rust, corrosion, and
97
cleanliness.
(Con't)
i. Check battery cable grommets for
dry rot, looseness or if missing. If
condition exists, contact Unit Main-
tenance for new grommets and
install.
Check right tandem housing oil level
98
Weekly
Right Tan-
on both sides. Dipstick is under fill
dem Oil
cap. Maintain the level between the
Level
ADD and FULL marks on the dip-
stick.
a. Check ROPS for loose, damaged, Loose, damaged, or missing
99
Weekly
ROPS
or missing mounting hardware. mounting hardware is noted.
Notify Unit Maintenance to
retorque/ replace mounting hard-
ware.
b. Check ROPS for any signs of Any signs of damage or
cracking in base metal or welded cracked welds are noted.
areas.
Perform the following test of air sys- Drop of air pressure is greater
100
Weekly
Air System
tem:
than 5 psi (35 kPa) in 10 min-
Pressure
utes.
Check
a. Start engine and allow air pressure
to reach 11010 psi (75869 kPa).
b. Apply and hold service brake
pedal. Shut down engine.
c. Reading on air pressure gauge
should not drop more then 5 psi (34
kPa) after the engine is stopped for
10 minutes.
0013 00-37