TM 5-3805-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL
HOURS
a. Remove two bolts and open right
95
rear engine access cover.
(Con't)
b. Check for loose connections and
Damage or evidence of leaks
damage to lines, fittings, and ether
is noted, or ether cylinder is
cylinder. Ensure cylinder is securely
missing, if required for mis-
mounted. Be alert for odor of leak-
sion.
ing ether.
c. Check and install protective cap
on fitting when ether cylinder is
not installed.
d. Close right rear engine access
cover. Install two bolts.
ETHER
BOTTLE
PROTECTIVE
CAP
397-1058
Check exhaust system pipes, clamps, Damage or leaks are noted.
96
Weekly
and muffler for looseness, leakage,
System
and damage.
0013 00-35