TM 5-3805-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL
HOURS
h. Check for rust, corrosion, and
93
cleanness.
(Con't)
i. Check battery cable grommets for
dry rot and loose or missing condi-
tion. If condition exists, contact
Unit Maintenance for new grom-
mets and install.
Check left tandem housing oil level on
94
Weekly
Left Tan-
both sides. Dipstick is under fill cap.
dem Oil
Maintain the level between the ADD
Level
and FULL marks on the dipstick.
TANDEM HOUSING
FILL CAP AND
DIPSTICK
397-1057
95
Weekly
Ether Cold
Start System
WARNING
Ether fuel is extremely flammable and toxic. DO NOT smoke
and make sure you are in a well-ventilated area away from
heat, open flames, or sparks. Wear eye protection. Avoid con-
tact with skin and eyes and avoid breathing ether fumes. If
fluid enters or fumes irritate the eyes, wash immediately with
large quantities of clean water for 15 minutes. Seek medical
attention immediately if ether is inhaled or causes eye irrita-
tion. Failure to follow this warning may cause injury or death
to personnel.
0013 00-34