Dry cleaning solvent (P-D-
680) used to clean parts is
toxic and flammable.
Use
only in
well
ventilated
areas.
Wear
protective
goggles and gloves.
Do not
smoke or allow open flames
or sparks in areas where
cleaning solvent is used or
stored.
Avoid contact with
eyes, skin, and clothing.
If contact is made, flush
with cold water and seek
medical attention.
If you
become
dizzy while
using
cleaning solvent, get fresh
air immediately.
Compressed
air
used
for
cleaning purposes will not
exceed 30 PSI.
Use only
with effective chip guarding
and
personal
protective
equipment
(goggles/shield,
gloves, etc.)
Clean retaining ring. screen and
plug in SD-IX. Dry thoroughly with
compressed air.
Install drain plug.
Install screen
and retaining ring.
Fill hydraulic tank.
Fill capacity
is approximately 8 gallons.
Install filler cap (13).
Start
engine and inspect for leaks.
Stop engine and check fluid level on
sight gage (12).
If necessary, add
fluid.
Level of fluid should be at
FULL mark.
Card 26 of 30
ANNUALLY (Cont) AND AS REQUIRED
LO 5-3805-261-12