TM 5-3805-293-23-5
0331
COOLANT HEATER INSTALLATION CONTINUED
000331
24. Measure and cut bulk hose to 67 in. (171 cm).
25. Route block heater inlet hose (Figure 40, Item 6) over engine.
26. Install clamp (Figure 40, Item 1), spacer (Figure 40, Item 2), clamp (Figure 40, Item 17), washer (Figure 40,
Item 3) and bolt (Figure 40, Item 4) on block heater inlet hose (Figure 40, Item 6) and hydraulic service pack
(Figure 40, Item 5).
27. Install bracket (Figure 40, Item 16), clip (Figure 40, Item 10), washer (Figure 40, Item 14), and bolt (Figure 40,
Item 15) on flywheel housing (Figure 40, Item 11).
28. Install clamp (Figure 40, Item 8), washer (Figure 40, Item 9), and bolt (Figure 40, Item 7) on block heater inlet
hose (Figure 40, Item 6) and bracket (Figure 40, Item 16).
29. Install new tiedown strap (Figure 40, Item 12) on electrical harness (Figure 40, Item 13).
Figure 40. Block Heater Inlet Hose Routing.
0331