TM 5-3805-293-23-3
0142
REMOVAL CONTINUED
31. Remove two tiedown straps (Figure 12, Item 2) and disconnect fan bypass solenoid connector (Figure 12,
Item 3) from fan bypass valve solenoid (Figure 12, Item 1).
Figure 12. Fan Bypass Solenoid.
0142
32. Remove tiedown strap (Figure 13, Item 5) from wiring harness (Figure 13, Item 6). Discard tiedown strap.
33. Disconnect transmission bypass solenoid connector (Figure 13, Item 11) from transmission solenoid
(Figure 13, Item 10). Position wiring harness aside.
34. Remove two bolts (Figure 13, Item 2), washers (Figure 13, Item 3), wiring harness clamps (Figure 13, Item 4)
and bracket (Figure 13, Item 1) from machine.
35. Remove two bolts (Figure 13, Item 7) and washers (Figure 13, Item 8) from transmission bypass solenoid
bracket (Figure 13, Item 9). Position transmission bypass solenoid bracket aside.
Figure 13. Transmission Bypass Solenoid.
0142