TM 5-3805-293-23-3
0142
REMOVAL CONTINUED
28. Remove two bolts (Figure 10, Item 1), washers (Figure 10, Item 4), and clamps (Figure 10, Item 5) from
transmission (Figure 10, Item 2) and position wiring harness (Figure 10, Item 3) aside.
Figure 10. Transmission ECM Connectors.
0142
29. Disconnect tube (Figure 11, Item 3) and remove O-ring (Figure 11, Item 2) from filter housing (Figure 11,
Item 1). Discard O-ring.
30. Disconnect tube (Figure 11, Item 3) and remove O-ring (Figure 11, Item 5) from fan bypass valve (Figure 11,
Item 4). Discard O-ring. Remove tube from machine.
Figure 11. Bypass Tube.
0142