TM 5-3805-293-23-3
0089
ASSEMBLY
00089
1. Install two tiedown clips (Figure 3, Item 7) on cooler housing (Figure 3, Item 3).
N OT E
Install studs on oil cooler only if removed.
Install studs on oil cooler as noted at removal.
2. Install four studs (Figure 3, Item 5) on cooler (Figure 3, Item 1).
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may cause injury to personnel.
C AU T I O N
Install plugs in oil cooler housing until flush with housing. Failure to follow this caution may
result in damage to equipment.
N OT E
Install plugs on oil cooler only if removed.
0089-4